{"id":1547,"date":"2018-01-20T16:00:10","date_gmt":"2018-01-20T16:00:10","guid":{"rendered":"https:\/\/global.sentec.com\/?p=1547"},"modified":"2025-03-09T17:16:58","modified_gmt":"2025-03-09T17:16:58","slug":"how-to-resolve-sensor-problem-11","status":"publish","type":"sentec-support","link":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/","title":{"rendered":"How to Resolve Sensor Problem 11"},"content":{"rendered":"<p>This message is commonly caused by a defective membrane or dried electrolyte. This video tutorial will guide you through the steps to resolve the error message.<\/p>\n<p><div class=\"fusion-video fusion-youtube fusion-aligncenter\" style=\"--awb-max-width:1000px;--awb-max-height:563px;--awb-width:100%;\"><div class=\"video-shortcode\"><div class=\"fluid-width-video-wrapper\" style=\"padding-top:56.3%;\" ><iframe title=\"YouTube video player 1\" src=\"https:\/\/www.youtube.com\/embed\/hMxj8CrGmGM?wmode=transparent&autoplay=0&amp;rel=0 &amp;modestbranding=1\" width=\"1000\" height=\"563\" allowfullscreen allow=\"autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture;\"><\/iframe><\/div><\/div><\/div><div class=\"fusion-text fusion-text-1\"><\/div><\/p>\n<div class=\"table-1\">\n<table width=\"100%\">\n<thead>\n<tr>\n<th align=\"left\">Possible Cause<\/th>\n<th align=\"left\">Recommended Action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\">Membrane related (defective or dried up electrolyte)<\/td>\n<td align=\"left\">Change the membrane:<br \/>\n1) if it is damaged or missing, has a loose fit, or if there is trapped air or dry electrolyte under the membrane<br \/>\n2) sensor calibration takes almost 14 minutes or cannot be completed within 14 minutes<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">PCO2 electrode and\/ or white PO2 sensing spot contaminated<\/td>\n<td align=\"left\">If after having changed the sensor membrane the calibration still takes almost 14 minutes or cannot be completed within 14 minutes contact qualified service personnel to clean the sensor without membrane.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Sentec TC Sensor defective<\/td>\n<td align=\"left\">If the problem persists the Sentec TC Sensor is defect. Replace it with a new one.<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><\/td>\n<td align=\"left\">For more troubleshooting information, see our <a class=\"download\" href=\"http:\/\/global.sentec.com\/fileadmin\/sites\/2\/documents\/Labeling\/Service_Manuals\/HB-005615-l-SDMS_Service-Manual-1.pdf\" target=\"_blank\" rel=\"noopener\">Service Manual<\/a>.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This message is commonly caused by a defective membrane or  [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":21984,"parent":0,"template":"","meta":{"_acf_changed":false,"content-type":"","inline_featured_image":false,"_links_to":"","_links_to_target":""},"sentec-care-settings":[238,239,240,235,236,237],"sentec-product-lines":[242],"sentec-product-support-type":[299],"class_list":["post-1547","sentec-support","type-sentec-support","status-publish","has-post-thumbnail","hentry","sentec-care-settings-adult-respiratory","sentec-care-settings-anesthesia-post-op","sentec-care-settings-home","sentec-care-settings-nicu","sentec-care-settings-picu","sentec-care-settings-sleep","sentec-product-lines-tcm","sentec-product-support-type-video"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.3 (Yoast SEO v28.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Resolve Sensor Problem 11 | Sentec Global<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Resolve Sensor Problem 11\" \/>\n<meta property=\"og:description\" content=\"This message is commonly caused by a defective membrane or [...]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/\" \/>\n<meta property=\"og:site_name\" content=\"Sentec Global\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-09T17:16:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2018\/01\/sensor-problem-11.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1001\" \/>\n\t<meta property=\"og:image:height\" content=\"562\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/\",\"url\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/\",\"name\":\"How to Resolve Sensor Problem 11 | Sentec Global\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/global.sentec.com\\\/fileadmin\\\/sites\\\/2\\\/2018\\\/01\\\/sensor-problem-11.png\",\"datePublished\":\"2018-01-20T16:00:10+00:00\",\"dateModified\":\"2025-03-09T17:16:58+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/#primaryimage\",\"url\":\"https:\\\/\\\/global.sentec.com\\\/fileadmin\\\/sites\\\/2\\\/2018\\\/01\\\/sensor-problem-11.png\",\"contentUrl\":\"https:\\\/\\\/global.sentec.com\\\/fileadmin\\\/sites\\\/2\\\/2018\\\/01\\\/sensor-problem-11.png\",\"width\":1001,\"height\":562},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/how-to-resolve-sensor-problem-11\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product Support Items\",\"item\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/produktsupport-material\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"How to Resolve Sensor Problem 11\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/\",\"name\":\"Sentec Global\",\"description\":\"Non-Invasive Respiratory Monitoring\",\"publisher\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#organization\",\"name\":\"Sentec\",\"url\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/global.sentec.com\\\/fileadmin\\\/sites\\\/2\\\/2022\\\/08\\\/sentec-logo-final-2.png\",\"contentUrl\":\"https:\\\/\\\/global.sentec.com\\\/fileadmin\\\/sites\\\/2\\\/2022\\\/08\\\/sentec-logo-final-2.png\",\"width\":1185,\"height\":257,\"caption\":\"Sentec\"},\"image\":{\"@id\":\"https:\\\/\\\/global.sentec.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Resolve Sensor Problem 11 | Sentec Global","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/","og_locale":"de_DE","og_type":"article","og_title":"How to Resolve Sensor Problem 11","og_description":"This message is commonly caused by a defective membrane or [...]","og_url":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/","og_site_name":"Sentec Global","article_modified_time":"2025-03-09T17:16:58+00:00","og_image":[{"width":1001,"height":562,"url":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2018\/01\/sensor-problem-11.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"1 Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/","url":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/","name":"How to Resolve Sensor Problem 11 | Sentec Global","isPartOf":{"@id":"https:\/\/global.sentec.com\/de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/#primaryimage"},"image":{"@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/#primaryimage"},"thumbnailUrl":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2018\/01\/sensor-problem-11.png","datePublished":"2018-01-20T16:00:10+00:00","dateModified":"2025-03-09T17:16:58+00:00","breadcrumb":{"@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/"]}]},{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/#primaryimage","url":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2018\/01\/sensor-problem-11.png","contentUrl":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2018\/01\/sensor-problem-11.png","width":1001,"height":562},{"@type":"BreadcrumbList","@id":"https:\/\/global.sentec.com\/de\/produktsupport-material\/how-to-resolve-sensor-problem-11\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/global.sentec.com\/de\/"},{"@type":"ListItem","position":2,"name":"Product Support Items","item":"https:\/\/global.sentec.com\/de\/produktsupport-material\/"},{"@type":"ListItem","position":3,"name":"How to Resolve Sensor Problem 11"}]},{"@type":"WebSite","@id":"https:\/\/global.sentec.com\/de\/#website","url":"https:\/\/global.sentec.com\/de\/","name":"Sentec Global","description":"Non-Invasive Respiratory Monitoring","publisher":{"@id":"https:\/\/global.sentec.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/global.sentec.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/global.sentec.com\/de\/#organization","name":"Sentec","url":"https:\/\/global.sentec.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/global.sentec.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2022\/08\/sentec-logo-final-2.png","contentUrl":"https:\/\/global.sentec.com\/fileadmin\/sites\/2\/2022\/08\/sentec-logo-final-2.png","width":1185,"height":257,"caption":"Sentec"},"image":{"@id":"https:\/\/global.sentec.com\/de\/#\/schema\/logo\/image\/"}}]}},"acf":[],"_links":{"self":[{"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/sentec-support\/1547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/sentec-support"}],"about":[{"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/types\/sentec-support"}],"author":[{"embeddable":true,"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/users\/2"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/media\/21984"}],"wp:attachment":[{"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/media?parent=1547"}],"wp:term":[{"taxonomy":"sentec-care-settings","embeddable":true,"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/sentec-care-settings?post=1547"},{"taxonomy":"sentec-product-lines","embeddable":true,"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/sentec-product-lines?post=1547"},{"taxonomy":"sentec-product-support-type","embeddable":true,"href":"https:\/\/global.sentec.com\/de\/wp-json\/wp\/v2\/sentec-product-support-type?post=1547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}